Diagnòstic del transductor lineal d'ultrasons Toshiba PLT-1204BT
Altres sondes Toshiba que podem oferir:
Marca | Model | Sistema compatible |
Toshiba/Canon | PLF-805ST | SSA-340A i SSA-350A |
Toshiba/Canon | PLM-1204AT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A/ Xario SSA-660A |
Toshiba/Canon | PLM-703AT | Powervision 6000 i Nemio |
Toshiba/Canon | PLM-805AT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PLT-1005BT | Aplio 300/ Aplio 400/ Aplio 500 |
Toshiba/Canon | PLT-1204AT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Sèrie Xario |
Toshiba/Canon | PLT-604AT | Sèrie Xario / Aplio 50 SSA-700A/ Aplio SSA-750A |
Toshiba/Canon | PLT-704AT | Aplio 50 SSA-700A/ SSA-750A/ Xario |
Toshiba/Canon | PLT-704SBT | Xario SSA-660A |
Toshiba/Canon | PLT-805AT | SSA-700A/ Aplio SSA-750A/ Aplio SSA-770A/ Xario SSA-660A |
Toshiba/Canon | PLU-1204BT | Xario 100/Xario 200 |
Toshiba/Canon | PSM-25AT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PSM-37CT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PST-25ST | t'estimo |
Toshiba/Canon | PST-30BT | Sèrie Xario i Aplio |
Toshiba/Canon | PST-30BT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Artida SSH-880CV/ Xario SSA-660A |
Toshiba/Canon | PSU-25BT (5S1) | Xario 100/ Xario 200 |
Toshiba/Canon | PSU-30BT (5S2) | Xario 100/ Xario 200 |
Toshiba/Canon | PVE-382M | 77B/90A/100A/240A/250A/TOSBEE |
Toshiba/Canon | PVF-375MT | SSH-140A/ SSA-270A/ SSA-340A |
Toshiba/Canon | PVM-375AT | PV 6000 SSA-370A/ Nemio 17 SSA-550A/ Nemio XG SSA-580A/ Nemio 30/ SSA-370A |
Toshiba/Canon | PVM-621VT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PVM-651VT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PVT-375BT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Aplio SSA-770A/ Aplio XG SSA-790A/ Xario SSA-660A/ SSA-680A |
Toshiba/Canon | PVT-375BT | SSA-700A/SSA-750A/ Aplio SSA-770A/SSA-790A/SSA-660A/ SSA-680A |
Toshiba/Canon | PVT-382BT | Aplio XG/Aplio MX/Xario XG/Xario/Viamo (2.0 i superior)/Aplio 500/Aplio 300 |
Toshiba/Canon | PVT-575MV | Xario SSA-660A/ Aplio XG |
Toshiba/Canon | PVT-661VT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario SSA-660A |
Toshiba/Canon | PVT-661VT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario SSA-660A |
Toshiba/Canon | PVT-674BT | Aplio 50 SSA-700A/ Aplio SSA-750A |
Toshiba/Canon | PVT-675MV | Xario 100/ Xario 200/ Aplio MX |
Toshiba/Canon | PVT-681MV | Aplio 300/ Aplio 400/ Aplio 500/ Xario XG |
Toshiba/Canon | PVT-712BT | Sèrie Aplio/ Sèrie Xario |
Toshiba/Canon | PVU-781VT | Xario |
Punt de coneixement
Imatge de flux Doppler color
El sistema d'imatge de flux Doppler en color pot mostrar simultàniament imatges de tipus B i dades de flux sanguini Doppler (direcció del flux sanguini, velocitat del flux, dispersió del flux) del sistema d'exploració d'ultrasò dual. Color power angio (CPA) va detectar l'energia retrodispersada de les cèl·lules sanguínies al flux sanguini, que no distingia la direcció del flux i no tenia res a veure amb l'angle θ (l'angle entre la direcció de l'ona sonora i la direcció del flux sanguini). ). El CPA pot millorar la sensibilitat de la detecció del flux sanguini, especialment adequat per mostrar el flux sanguini a baixa velocitat dels vasos petits, però no pot mostrar la direcció del flux sanguini.