Peralatan Medis Probe Transduser Ultrasound Sektor Toshiba PSU-30BT 5S2
Probe Toshiba lainnya yang dapat kami tawarkan:
Merek | Model | Sistem yang Kompatibel |
Toshiba/Kanon | PLF-805ST | SSA-340A & SSA-350A |
Toshiba/Kanon | PLM-1204AT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A/ Xario SSA-660A |
Toshiba/Kanon | PLM-703AT | Powervision 6000 dan Nemio |
Toshiba/Kanon | PLM-805AT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Kanon | PLT-1005BT | Aplio 300/ Aplio 400/ Aplio 500 |
Toshiba/Kanon | PLT-1204AT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Seri Xario |
Toshiba/Kanon | PLT-604AT | Seri Xario / Aplio 50 SSA-700A/ Aplio SSA-750A |
Toshiba/Kanon | PLT-704AT | Aplio 50 SSA-700A/ SSA-750A/ Xario |
Toshiba/Kanon | PLT-704SBT | Xario SSA-660A |
Toshiba/Kanon | PLT-805AT | SSA-700A/ Aplio SSA-750A/ Aplio SSA-770A/ Xario SSA-660A |
Toshiba/Kanon | PLU-1204BT | Xario 100/Xario 200 |
Toshiba/Kanon | PSM-25AT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Kanon | PSM-37CT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Kanon | PST-25ST | Aku mencintaimu |
Toshiba/Kanon | PST-30BT | Seri Xario & Aplio |
Toshiba/Kanon | PST-30BT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Artida SSH-880CV/ Xario SSA-660A |
Toshiba/Kanon | PSU-25BT(5S1) | Xario 100/ Xario 200 |
Toshiba/Kanon | PSU-30BT(5S2) | Xario 100/ Xario 200 |
Toshiba/Kanon | PVE-382M | 77B/90A/100A/240A/250A/TOSBEE |
Toshiba/Kanon | PVF-375MT | SSH-140A/ SSA-270A/ SSA-340A |
Toshiba/Kanon | PVM-375AT | PV 6000 SSA-370A/ Nemio 17 SSA-550A/ Nemio XG SSA-580A/ Nemio 30/ SSA-370A |
Toshiba/Kanon | PVM-621VT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Kanon | PVM-651VT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Kanon | PVT-375BT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Aplio SSA-770A/ Aplio XG SSA-790A/ Xario SSA-660A/ SSA-680A |
Toshiba/Kanon | PVT-375BT | SSA-700A/SSA-750A/ Aplio SSA-770A/SSA-790A/SSA-660A/ SSA-680A |
Toshiba/Kanon | PVT-382BT | Aplio XG/Aplio MX/Xario XG/Xario/Viamo (2.0 dan lebih tinggi)/Aplio 500/Aplio 300 |
Toshiba/Kanon | PVT-575MV | Xario SSA-660A/ Aplio XG |
Toshiba/Kanon | PVT-661VT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario SSA-660A |
Toshiba/Kanon | PVT-661VT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario SSA-660A |
Toshiba/Kanon | PVT-674BT | Aplio 50 SSA-700A/ Aplio SSA-750A |
Toshiba/Kanon | PVT-675MV | Xario 100/ Xario 200/ Aplio MX |
Toshiba/Kanon | PVT-681MV | Aplio 300/ Aplio 400/ Aplio 500/ Xario XG |
Toshiba/Kanon | PVT-712BT | Seri Aplio/seri Xario |
Toshiba/Kanon | PVU-781VT | Xario |
Poin pengetahuan
Pencitraan harmonis
Pencitraan harmonik memanfaatkan propagasi USG non-linier melalui jaringan tubuh. Bila frekuensi gelombang bunyi yang dipancarkan adalah f 0, maka frekuensi gema (akibat pemantulan atau hamburan) meliputi f 0 (disebut gelombang fundamental), 2f 0, 3F 0 dan seterusnya. Harmonik kedua (2f 0) mempunyai energi terbesar .
Pencitraan harmonik ultrasonik (UHI) didasarkan pada informasi tubuh manusia yang dibawa oleh harmonik kedua dalam gema (pantulan atau hamburan). Pencitraan harmonik tanpa UCA disebut pencitraan harmonik asli atau pencitraan harmonik jaringan. Pencitraan harmonik menggunakan UCA (agen kontras USG) disebut pencitraan harmonik kontras.