Apparato medico con sonda per trasduttore a ultrasuoni settoriale Toshiba PSU-30BT 5S2
Altre sonde Toshiba che possiamo offrire:
Marca | Modello | Sistema compatibile |
Toshiba/Canon | PLF-805ST | SSA-340A e SSA-350A |
Toshiba/Canon | PLM-1204AT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A/ Xario SSA-660A |
Toshiba/Canon | PLM-703AT | Powervision 6000 e Nemio |
Toshiba/Canon | PLM-805AT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PLT-1005BT | Aplio 300/Aplio 400/Aplio 500 |
Toshiba/Canon | PLT-1204AT | Serie Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario |
Toshiba/Canon | PLT-604AT | Serie Xario / Aplio 50 SSA-700A/ Aplio SSA-750A |
Toshiba/Canon | PLT-704AT | Aplio 50 SSA-700A/ SSA-750A/Xario |
Toshiba/Canon | PLT-704SBT | XarioSSA-660A |
Toshiba/Canon | PLT-805AT | SSA-700A/ Aplio SSA-750A/ Aplio SSA-770A/ Xario SSA-660A |
Toshiba/Canon | PLU-1204BT | Xario100/Xario200 |
Toshiba/Canon | PSM-25AT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PSM-37CT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PST-25ST | Viamo |
Toshiba/Canon | PST-30BT | Serie Xario e Aplio |
Toshiba/Canon | PST-30BT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Artida SSH-880CV/ Xario SSA-660A |
Toshiba/Canon | PSU-25BT(5S1) | Xario 100/ Xario 200 |
Toshiba/Canon | PSU-30BT(5S2) | Xario 100/ Xario 200 |
Toshiba/Canon | PVE-382M | 77B/90A/100A/240A/250A/TOSBEE |
Toshiba/Canon | PVF-375MT | SSH-140A/ SSA-270A/ SSA-340A |
Toshiba/Canon | PVM-375AT | PV 6000 SSA-370A/ Nemio 17 SSA-550A/ Nemio XG SSA-580A/ Nemio 30/ SSA-370A |
Toshiba/Canon | PVM-621VT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PVM-651VT | PowerVision 6000 SSA-370A/ Nemio 17 SSA-550A |
Toshiba/Canon | PVT-375BT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Aplio SSA-770A/ Aplio XG SSA-790A/ Xario SSA-660A/ SSA-680A |
Toshiba/Canon | PVT-375BT | SSA-700A/SSA-750A/ Aplio SSA-770A/SSA-790A/SSA-660A/ SSA-680A |
Toshiba/Canon | PVT-382BT | Aplio XG/Aplio MX/Xario XG/Xario/Viamo (2.0 e versioni successive)/Aplio 500/Aplio 300 |
Toshiba/Canon | PVT-575MV | Xario SSA-660A/Aplio XG |
Toshiba/Canon | PVT-661VT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario SSA-660A |
Toshiba/Canon | PVT-661VT | Aplio 50 SSA-700A/ Aplio SSA-750A/ Xario SSA-660A |
Toshiba/Canon | PVT-674BT | Aplio 50 SSA-700A/ Aplio SSA-750A |
Toshiba/Canon | PVT-675MV | Xario 100/ Xario 200/ Aplio MX |
Toshiba/Canon | PVT-681MV | Aplio 300/ Aplio 400/ Aplio 500/ Xario XG |
Toshiba/Canon | PVT-712BT | Serie Aplio/serie Xario |
Toshiba/Canon | PVU-781VT | Xario |
Punto di conoscenza
Immagine armonica
L'imaging armonico sfrutta la propagazione non lineare degli ultrasuoni attraverso i tessuti del corpo. Quando la frequenza dell'onda sonora emessa è f 0, la frequenza dell'eco (dovuta alla riflessione o alla diffusione) include f 0 (chiamata onda fondamentale), 2f 0, 3F 0 e così via La seconda armonica (2f 0) ha l'energia maggiore .
L'imaging armonico ultrasonico (UHI) si basa sulle informazioni del corpo umano trasportate dalla seconda armonica nell'eco (riflessione o diffusione). L'imaging armonico senza UCA è chiamato imaging armonico nativo o imaging armonico dei tessuti. L'imaging armonico che utilizza l'UCA (agente di contrasto per ultrasuoni) è chiamato imaging armonico di contrasto.