0102030405
Aloka Alpha 6 EP555501AA Ultrasound Spare Parts Beamformer
Iba pang Hitachi ultrasonic board na maaari naming palitan/alok.
Tatak | sistema | Paglalarawan | Numero ng bahagi |
anino | Alpha 5 | motherboard | EP493700DD |
anino | Alpha 6 | RX Beam Dating | EP555501AA |
anino | Alpha 6 | CW board | EP555700 |
anino | Alpha 6 | CPU mainboard | EP537000/EP563000 |
anino | Alpha 6 | TX/RX | EP555300 |
anino | Alpha 6/Alpha 7 | DOM | EP550000AA |
anino | Alpha 7 | RX Beam Dating | EP539100BB/EP539500DG/EP539501DG |
anino | Alpha 7 | CPU mainboard | EP558900 |
anino | Alpha 7 | TI Board | EP539000 |
anino | Alpha 7 | TX board | EP548300BB |
anino | Alpha 7 | touch screen | L-Key-93H |
anino | Alpha 10 | RX Beamformer board | EP531800CE |
anino | Alpha 10 | wave generator Board | EP495000HH/EP495000HJ/EP495000FF |
anino | Alpha 10 | Mataas na boltahe na Lupon | EP541800 |
anino | Alpha 10 | CPU mainboard | EP496000 |
Hitachi | F31 | RX Beamformer board | EP568900 |
Hitachi | F31 | motherboard | EP575700BC/EP560800 |
Hitachi | F37 | TX/RS | EP557400/EP557300 |
Hitachi | F37 | motherboard | EP575700BC/EP560800 |
Hitachi | F37 | BF Beamformer board | EP557400 |
Hitachi | F37 | RX mainboard | EP557500 |
anino | F75 | CONT-B | EP556700BB |
anino | F75 | USP board | EP556600 |
anino | F75 | Cell Board | EP558800 |
Hitachi | HI VISION Avius | RDBF board | 7513907A/7513612 |
Hitachi | HI VISION Avius | CONT-B | 7513734A |
Hitachi | HI VISION Avius/Preirus | Cell board | 7345930A |
Hitachi | HI VISION Preirus | Lupon ng RX | CZH4AA |
Hitachi | HI VISION Preirus | Lupon ng TX | 7513629A |
Hitachi | HI VISION Preirus | CONT-B | 7513640A/CZ84AJ |
Hitachi | Arietta 60 | TX | |
Hitachi | Arietta 60 | RX | |
Hitachi | Arietta 60 | CELL | EU-9160C |
Hitachi | Arietta 70 | TX | EP572300AA |
Hitachi | Arietta 70 | RX | EP572900/EP572200 |
Hitachi | Arietta 70 | CELL | |
Hitachi | Noblus | CELL | |
Hitachi | Noblus | CONT-B | |
Hitachi | Paakyat | TX | |
Hitachi | Paakyat | CELL | 7352830A |
Punto ng kaalaman
Mga karaniwang pagkabigo ng color Doppler ultrasound
1. Pagkabigo ng control panel
2. System software, application software failure
3. Pagkabigo sa back end
4. Power failure (Pangunahing power supply, Low-voltage power supply, High-voltage power supply)
5. Pagkabigo ng Transducer Probe
6. Front-end failure (Interface board, Transmitter, Receiver, Control, VIDEO, Front-end na koneksyon)
7. Nabigo ang display (Display, Workstation, Touch screen)
8. Kabiguan na dulot ng panlabas na kapaligiran