Leave Your Message

Power Board 5201018-2 for GE Logiq E9 Ultrasound System

1. Compatible system: GE Logiq E9
2. Warranty: 60 days
3. Part number: 5201018-2

    GE Logiq E9 Ultrasound System Power Board 5201018-2

    About GE Logiq E9 Power Board Information

    1. Power Board Overview
    In the GE Logiq E9 ultrasound diagnostic system, the Power Board is an important part of the system power management. It is mainly responsible for providing a stable and reliable power supply for the entire system to ensure that the equipment can operate normally. The Power Board usually contains multiple circuit modules for converting, distributing and protecting power to meet the power requirements of various components of the system.

    2. Functions of the Power Board
    Power conversion: convert the input alternating current (AC) into the direct current (DC) required by the device, or perform other necessary voltage and current conversions.
    Power distribution: distribute the converted power to various components of the system, such as the main power supply (Main Power), back-end processor (BEP), front-end circuit board box (Front Plane), etc.
    Power protection: has safety functions such as overload protection and short circuit protection to prevent damage to the equipment due to power abnormalities.

    3. Power Board Failure and Repair
    During the use of the GE Logiq E9, the Power Board may fail, causing the device to fail to start or run normally. The following are some common failure phenomena and repair methods:

    The device cannot start: If the device cannot start after power is turned on, it may be that the power conversion function of the Power Board has failed. At this time, you need to check whether the input voltage of the Power Board is normal and whether the power conversion circuit is damaged.
    Abnormal power indicator: If the power indicator of the Power Board shows abnormality (such as not lit, flashing, etc.), there may be a problem with the power distribution or protection circuit. At this time, you need to further check the relevant circuit modules to determine the cause of the fault and repair it.
    Automatic shutdown of the device: If the device automatically shuts down during use, it may be that the power protection function of the Power Board is triggered. At this time, you need to check whether there are abnormal conditions such as overload and short circuit, and take corresponding measures to solve the problem.

    5. Repair suggestions
    For the repair of the Power Board fault of GE Logiq E9, it is recommended to follow the following steps:

    Power off check: Be sure to cut off the power supply of the device before repair to avoid the risk of electric shock.
    Troubleshooting: According to the fault phenomenon and the working principle of the Power Board, step by step to troubleshoot possible causes of the fault.
    Replacement of parts: If it is determined that a certain circuit module is damaged and causes the fault, the corresponding parts need to be replaced in time. Pay attention to choosing the model and specifications that match the original parts.
    Test verification: After the repair is completed, the device needs to be fully tested and verified to ensure that the fault has been eliminated and the device can operate normally.

    The Power Board of GE Logiq E9 is a key component of system power management. Its stability and reliability are crucial to the normal operation of the device. During use, if there is a problem related to the Power Board, it is necessary to conduct timely troubleshooting and repair to ensure the normal use of the device. At the same time, it is recommended to regularly maintain and service the device to extend its service life and reduce the probability of failure.

     

    Other GE related ultrasonic components we can offer:

     
    Brand System Description
    GE Logiq E9/vivid E9 GTX 2.4/GTX-TLP 3.0  P/N:5201044-3,5201044-4, 5201044-5 / GA200625-3
    GE Logiq E9 MRX Board 5393908
    GE Logiq E9/vivid E9 GFI2 25161631
    GE Logiq E9 BEP Power 5393800-3,5166790-2/5393801
    GE Logiq E9 Main power supply (5205052-3)
      Logiq E9 Contral board 9375-00639-001/2
    GE Logiq E9/vivid E9 Touch screen CORE OPERATOR PANEL, UPPER 4- touch panel  GB200091/5207000-53
    GE Logiq E9 trackball
    GE Logiq E9 LCD monitor  5392293-21/ KT-LM190SDG-U
    GE Voluson E6/E8 RSR14.P9 KTI196357
    GE Voluson E6/E8 RST20.P8 KTI301148_2
    GE Voluson E6/E8/E10 RSX
    GE Voluson E6/E8/E10 RFM201 FE mainboard
    GE Voluson E6/E8/E10 RFM221 FE mainboard
    GE Voluson E6/Voluson E8 RFI/ RFI21b Board KTI300614-4 /KTI302197-6
    GE Voluson E6/Voluson E9 KTI302171-4
    GE Voluson E6/Voluson E8 RSR KTI301394-2/KTI196357/KTZ196310
    GE Voluson E6/Voluson E8 AC/DC Power KTI300627-4/KTI300242-3
    GE Voluson E6/Voluson E8 power supply-KTZ302752
    GE Voluson E6/Voluson E8 GBF80A KTI300741
    GE Voluson E6/Voluson E8 GE Voluson E8  C2D E6400 BEP Board # KTI302072