About Philips HD11 control Board
1. Control panel layout
The layout of the Philips HD11 control panel is usually designed with ease and intuitiveness in mind, allowing doctors or technicians to quickly and accurately adjust various parameters and settings. The control panel may include the following main parts:
Display: used to display ultrasound images and related information to help doctors make diagnoses.
Physical key area: includes various function keys and adjustment keys, such as brightness adjustment, contrast adjustment, gain control, depth adjustment, focus adjustment, etc. These keys allow doctors to make real-time adjustments to ultrasound images as needed.
Trackball or touchpad: Some Philips HD11 models may be equipped with a trackball or touchpad for more flexible control of image movement, zooming, and rotation.
Softkey area: One or more rows of soft keys located below or on the side of the display, used to execute specific menu commands or functions. The specific functions of these soft keys will change depending on the currently selected menu or mode.
2. Control panel functions
The Philips HD11 control panel provides a wealth of functions to meet different clinical diagnostic needs. Here are some of the main functions:
Image control: Through the adjustment keys such as brightness, contrast, and gain on the control panel, doctors can make real-time adjustments to the ultrasound image to obtain the best visual effect and diagnostic accuracy.
Scan parameter setting: The control panel allows doctors to set parameters such as the depth of ultrasound scanning and the position of the focus point to adapt to different examination sites and needs.
Imaging mode selection: Philips HD11 supports a variety of imaging modes, such as B mode, M mode, color Doppler mode, etc. Doctors can select the appropriate imaging mode through the relevant buttons or menu options on the control panel.
Measurement and annotation: The measurement and annotation functions on the control panel allow doctors to measure distance, area, circumference, etc. on ultrasound images, and add annotation information such as text and arrows to assist in diagnosis.
System settings: Through the system settings options on the control panel, doctors can set and manage the language, time, user permissions, etc. of the device.
III. Operation precautions
Familiar with the operation manual: Before operating Philips HD11, it is recommended that doctors or technicians carefully read and familiarize themselves with the operation manual of the device and understand the detailed description of each button and function on the control panel.
Gentle operation: During operation, the buttons and knobs should be pressed gently to avoid excessive force that may damage the equipment or affect the inspection results.
Regular maintenance and care: Regularly maintain and care for Philips HD11, including cleaning the control panel, checking the flexibility of buttons and knobs, etc., to ensure the normal operation of the equipment and extend its service life.
Other ultrasound parts related to that we can offer:
Brand | Machine type | Part type/number |
Philips | HD3 | Main board BD-439-PCC |
Philips | HD3 | Philips HD3 |
Philips | HD3 | power supply |
Philips | HD6 | power supply |
Philips | HD7 | Keyboard/control board (p/n:453561194831) |
Philips | HD7 | TR board M2540-60040F |
Philips | HD7 | LCD Monitor 453561350091(454110240251) |
Philips | HD7 | Main board RB945G ATX (Version Rev 1.0) |
Philips | HD7 | Main board M2540-60060 |
Philips | HD7 | Interface board M2540-60070/M2540-60270 |
Philips | HD7 XE | LCD Monitor |
Philips | HD9 | PSA board BD445PSA 0A |
Philips | HD9 | BF board (P/N: BD-445-BF) |
Philips | HD9 | MTR BD-445-MTR |
Brand | Machine type | Part type/number |
Philips | HD11/HD11XE | TR board Front-end M2540-20240 back-end M2540-60240 |
Philips | HD11 | HD11 LCD Monitor |
Philips | HD11 | APIO 453561183003 |